Biomag – pulsed magnetic therapy
Profesionalne medicinske naprave in aplikatorji za pulzno magnetoterapijo.
 


Nič več aktualni aplikatorji


Devices Biomag® are provided with a wide choice of applicators, in order to allow comfortable and efficient application by means of pulse magnetic field. Dimensions of the applicators, the shape and the technical parameters are designed so that they suit best to the intended application. All applicators are designed with surface made of hygienically unobjectionable materials.

Flat applicators
Flat applicators are able to excite a magnetic field of highest intensity; however, the field is rather inhomogeneous in space. The magnetic field intensity decreases according to the distance from the applicator surface (e.g. at distance of 8 cm the intensity drops to mere 20% of the value on the surface). They are used in case we do not require penetration of the magnetic field in the tissues deep under the surface. The most powerful magnetic field is in the axis near the surface. The distribution of the pulse magnetic field intensity may be verified by means of a testing magnet (included in the supply).

Cylindrical or ring-shaped applicators
Cylindrical and ring-shaped applicators operate with a homogenous field, however, the intensity is little lower in comparison to the flat applicators. They are used in case that even effects of the magnetic field are emphasised, and if we need the field to penetrate deep in the tissue (e.g. if applied on extremity joints). You may verify the range of the spatial pulse magnetic field with a testing magnet as well.


Magnetotherapy - general description

Applicators are air coils wound of enamelled copper or other special wire in a special construction. The surface of the applicator meets user requirements and relevant standards: it is made of tow quality leatherette that complies with hygienic norms for contact with epidermis.

Among the applicators available in the offer (see below), you should always select the most suitable for the particular therapeutic purpose. The applicator should be placed as close to the surface of the part subjected to the therapy as possible (with applicators -solenoids that produce a spatial pulse magnetic field, it is enough if the part of the body is located within the solenoid space). In order to make the best decision on which applicator should be applied, use the following criteria: the applicator should be placed on the body comfortably, as close to the affected part as possible; you should consider whether you need to apply the treatment in the depth (solenoid) or whether just a flat applicator would serve well for the given purpose.

The applicator may be connected to, or disconnected from, the machine connector only if the machine is not running, which means the state while the output connector is without voltage (the PA indication is active, the pulse control diode is neither flashing nor lit).

You should protect the surface of applicators against mechanical damage (e.g. breakthrough or cutting through the leatherette). In addition, neither the connector nor the inlet cable may be damaged.

With some applicators, the presence of the magnetic field is signalled with a diode that is flashing in the rhythm of the pulses. As for faster pulses, the diode is permanently lit. It is forbidden to use damaged applicators or applicators with damaged cables or connectors! Apply the applicators to the body over clothes or suitable mask.

Magnetotherapy - SOLENOID S1H 50

The magnetic induction in the coil axis on the surface of the applicator: 4 mT
Dimensions: diameter 500 mm, depth 345 mm
Weight: 8,9 kg

magnetotherapy-applicators-SOLENOID S1H 50

magnetotherapy-applicators-SOLENOID S1H 50

Usage and operation time: Big solenoid. The applicator generates a spatial pulse magnetic field - suitable for depth applications. Suitable for applications on the back, hips and other joints, cervical spinal column, body applications. Application over a textile pad on the afflicted spot, as close as possible to the surface of the body. For the operation time and other instructions, follow the manual of the particular device to be used with the applicator.

go to Biomag® recommended sets


Magnetotherapy - SOLENOID S1HLg 50

The magnetic induction in the coil axis on the surface of the applicator: 4 mT
Dimensions: inside diameter 440 mm, full 510 mm, depth 120 mm, thickness 8 mm
Weight: 3,3 kg

magnetotherapy-applicators-SOLENOID S1HLg 50

magnetotherapy-applicators-SOLENOID S1HLg 50

Usage and operation time: Big solenoid. The applicator generates a spatial pulse magnetic field - suitable for applications on back, hips, joints, cervical spinal column, and body applications. To be used over a textile pad on the spot afflicted or a part of it. Made on order, the type with the solenoid diameter increased by 6 cm may be supplied (the same characteristics).

go to Biomag® recommended sets


Magnetotherapy - SOLENOID S5HLg

The magnetic induction in the coil axis on the surface of the applicator: 2,7 mT
Dimensions: diameter 300 mm, depth 170 mm
Weight: 2,75 kg

magnetotherapy-applicators-SOLENOID S5HLg

magnetotherapy-applicators-SOLENOID S5HLg

Usage and operation time: Medium solenoid. The applicator generates an advantageous spatial pulse magnetic field - suitable for depth applications. To be used for application on joints, cervical spinal column, head. Application over a textile pad on the afflicted spot, as close as possible to the surface of the body. For the operation time and other instructions, follow the manual of the particular device to be used with the applicator.

go to Biomag® recommended sets


Magnetotherapy - SOLENOID SPH2Lg

The magnetic induction in the coil axis on the surface of the applicator: 4 mT
Dimensions: 240 mm, 140 mm
Weight: 1,46 kg

magnetotherapy-applicators-SOLENOID SPH2Lg

magnetotherapy-applicators-SOLENOID SPH2Lg

Usage and operation time: The applicator generates a spatial pulse magnetic field - suitable for depth applications. To be used for application on joints, cervical spinal column, head. Application over a textile pad on the afflicted spot, as close as possible to the surface of the body. For the operation time and other instructions, follow the manual of the particular device to be used with the applicator.

go to Biomag® recommended sets


Magnetotherapy - SOLENOID SPHLg

The magnetic induction in the coil axis on the surface of the applicator: 4,7 mT
Dimensions: diameter 240, depth 80 mm
Weight: 1,1 kg

magnetotherapy-applicators-SOLENOID SPHLg

magnetotherapy-applicators-SOLENOID SPHLg

Usage and operation time: To be used for application on joints, cervical spinal column, head. The applicator generates a spatial magnetic field - suitable for depth applications. To be used over a textile pad on the spot afflicted or a part of it.

go to Biomag® recommended sets


Magnetotherapy - paddy applicator A3H Lg MAX Part A

The magnetic induction in the coil axis on the surface of the applicator: 5 mT
Dimensions: 860 x 480 x 35 mm
Weight: 2,37 kg

magnetotherapy-applicators-Paddy applicator A3H Lg MAX Part A

magnetotherapy-applicators-Paddy applicator A3H Lg MAX Part A

Usage and operation time: To be used as a rehabilitation applicator on the back, or together with the part B as a whole-bed rehabilitation applicator. Application over a textile pad. Extremely suitable for wholebody applications - prevention, rehabilitation, blood circulation promotion, muscle release.

go to Biomag® recommended sets


Magnetotherapy - paddy applicator A3H Lg MAX Part B

The magnetic induction in the coil axis on the surface of the applicator: 5,5 mT
Dimensions: 860 x 480 x 35 mm
Weight: 1,99 kg

magnetotherapy-applicators-Paddy applicator A3H Lg MAX Part B

magnetotherapy-applicators-Paddy applicator A3H Lg MAX Part B

Usage and operation time: To be used as a rehabilitation applicator on the back, or together with the part A as a whole-bed rehabilitation applicator. The upper part marked with enlarged seamwork is intended for whole-bed application - for the patient's head: it does not generate the magnetic field.

go to Biomag® recommended sets


Magnetotherapy - paddy applicator A4H Lg

The magnetic induction in the coil axis on the surface of the applicator: 14mT
Dimensions: 480 x 460 x 35 mm
Weight: 1,7 kg

magnetotherapy-applicators-Paddy applicator A4H Lg

magnetotherapy-applicators-Paddy applicator A4H Lg

Usage and operation time: Area paddy foldaway applicator. To be used for applications on the back, for long bones and muscles.

go to Biomag® recommended sets


Magnetotherapy - paddy applicator A3H Lg

The magnetic induction in the coil axis on the surface of the applicator: 16 mT
Dimensions: width 670 x height 220 x depth 35 mm
Weight: 1,62 kg

magnetotherapy-applicators-Paddy applicator A3H Lg

magnetotherapy-applicators-Paddy applicator A3H Lg

Usage and operation time: Three-part foldaway paddy applicator. Various options of how to use it within the dimensions of the applicator. Application over a textile pad on the afflicted spot, as close as possible to the surface of the body.

go to Biomag® recommended sets


Magnetotherapy - applicator A2H Lg Width 330 mm

The magnetic induction in the coil axis on the surface of the applicator: 14 mT
Dimensions: width 330 x height 475 x depth 35 mm
Weight: 1,43 kg
Folding pad applicator.

magnetotherapy-applicators-Applicator A2H Lg Width 330 mm

magnetotherapy-applicators-Applicator A2H Lg Width 330 mm

Usage and operation time: To be used for back, joints, muscles, bones. Enlarged and more flexible version of the previous applicator. On request, the version DUO may be supplied, i.e. 2 applicators A2HLg, width 330; they may be zipped together (only for double-output machines). This way, you may take advantage of the application area 330 x 960 mm.

go to Biomag® recommended sets


Magnetotherapy - applicator A2H Lg Width 250 mm

The magnetic induction in the coil axis on the surface of the applicator: 12 mT
Dimensions: 250 x 480 x 35mm (w, h, d)
Weight: 1,3 kg

magnetotherapy-applicators-AApplicator A2H Lg Width 250 mm

magnetotherapy-applicators-Applicator A2H Lg Width 250 mm

Usage and operation time: Used as a flexible applicator, or with muscles, joints and bones, or, if suitable, for other types of applications. Flexible two-part applicator. Application over a textile pad on the spot afflicted, as close to the surface of the body as possible. For the time of operation and other parameters see the instructions of the manufacturer of the machine to be used with. Using a fixing tape you may fix the applicator to the body more comfortably in order to reach better effects of the application.

go to Biomag® recommended sets


Magnetotherapy - A1H Lg - without vibration

MThe magnetic induction in the coil axis on the surface of the applicator: 40 mT
Dimensions: diameter 110mm, height 29mm
Weight: 0,45 kg

magnetotherapy-applicators-A1H Lg - without vibration

magnetotherapy-applicators-A1H Lg - without vibration

Usage and operation time: Local disc applicator. To be used for local applications or as a stomatological applicator as well. Application over a textile pad on the afflicted spot, as close as possible to the surface of the body. In order to fix it to the position for application, you may use the fixing tape.

go to Biomag® recommended sets


Magnetotherapy - A1H Lg - with vibration

The magnetic induction, i.e. the force of the magnetic field in the coil axis on the surface of the applicators: 36 mT
Dimensions: diameter 110mm, height 29mm
Weight: 0,60 kg

magnetotherapy-applicators-A1H Lg - with vibration

magnetotherapy-applicators-A1H Lg - with vibration

Usage and operation time: Local disc applicator. To be used for local applications or as a stomatological applicator as well. The vibration may be used at fine massage of nerve endings of certain organs - e.g. feet. Along with that, the blood circulation is promoted and oxygen supply is improved. In order to fix it to the position for application, you may use the fixing tape.

go to Biomag® recommended sets


Magnetotherapy - paddy applicator A1HPLg

Magnetic induction in the coil axis on the surface of the applicator: 15 mT
Dimensions: 260 x 220 x 40mm, Weight: 0.81 kg
Weight: 0,81 kg

magnetotherapy-applicators-Paddy applicator A1HPLg

magnetotherapy-applicators-Paddy applicator A1HPLg

Usage and operation time: For local use – muscles, joints and bones and/or other suitable kinds of application. The applicator is equipped with a fastener enabling connection to another applicator or the orthopaedic aid FIX DUO 250 => increase of the effective application surface. Application through a layer of a textile on the affected site as close as possible to the body surface.

go to Biomag® recommended sets


Magnetotherapy - orthopedic aid FIX DUO 250

Dimensions: width 250 x height 250 x depth 35 mm
Weight: 0,335 kg
Intensity of the permanent magnetic field: 20 mT

magnetotherapy-applicators-Orthopedic aid FIX DUO 250

magnetotherapy-applicators-Orthopedic aid FIX DUO 250

Usage and operation time: Orthopedic aid intended for fixation of the applicator A2HLg 250 or A1HPLg.

go to Biomag® recommended sets


Magnetotherapy - orthopedic aid FIX DUO 330

Dimensions: width 330 x height 260 x depth 35 mm
Weight: 0,430 kg
IIntensity of the permanent magnetic field: 20 mT

magnetotherapy-applicators-Orthopedic aid FIX DUO 330

magnetotherapy-applicators-Orthopedic aid FIX DUO 330

Usage and operation time: Orthopedic aid intended for fixation of the applicator A2HLg 330.

go to Biomag® recommended sets


Magnetotherapy - orthopedic aid FIX 700

Dimensions: width 650 x height 160 x depth 35 mm
Weight: 0,280 kg
Intensity of the permanent magnetic field: 20 mT

magnetotherapy-applicators-Orthopedic aid FIX 700

magnetotherapy-applicators-Orthopedic aid FIX 700

Usage and operation time: Orthopedic aid intended for connection of 2 pieces of applicators A1HPLg - for application on both shoulders at a time.